    Abstract:

    This paper introduces the design, analysis and experimental verification of focal spot X-ray in-line imaging system. First of all, the object transmission function is fixed by the refractive index decrement and the absorption index of tissue according to the previously selected energy. After the factors being analyzed, such as the distance between the object and detector, and the object edge width, which can affect imaging quality, methods presented to improve image resolution are validated. In the experiment, plastic set square is irradiated with X-ray phase-contrast technique. The result is then compared with that using traditional X-ray imaging technique. The experimental results exhibit considerable consistency with former numerical simulation, which proves that the particular method can be used to determine the parameters of imaging system.

    Reference
    [1] Wu XZ, Liu H. A general theoretical formalism for X-ray phase contrast imaging. Journal of X-Ray Science and Technology, 2003,11(1):33?42.
    [2] Lewis RA. Medical phase contrast X-ray imaging: Current status and future prospects. Physics in Medicine and Biology, 2004, 49(16):3573?3583.
    [3] Jiang QJ, Xiao XS, Liu SY, Xiao TQ, Chen M. Initial study of synchrotron X-ray phase-contrast imaging: Experimental imaging of rats liver and lung in vitro. Chinese Journal of Medical Imaging Technology, 2003,19(9):1116?1117 (in Chinese with English abstract).
    [4] Pogany A, Gao D, Wilkins SW. Contrast and resolution in imaging with a microfocus X-ray source. Review of Scientific Instruments, 1997,68(7):2774?2782.
    [5] Gureyev TE, Wilkins SW. On X-ray phase imaging with a point source. Journal of the Optical Society of America A, 1998,15(3): 579?585.
    [6] Kotre CJ, Birch IP. Phase contrast enhancement of X-ray mammography: A design study. Physics in Medicine and Biology, 1999, 44(11):2853?2866.
    [7] Davis TJ, Gao D, Gureyev TE, Stevenson AW, Wilkins SW. Phase-Contrast imaging of weakly absorbing materials using hard X-rays. Nature, 1995,373(6515):595?598.
    [8] Wilkins SW, Gureyev TE, Gao D, Pogany A, Stevenson AW. Phase-Contrast imaging using polychromatic hard X-rays. Nature, 1996,384(6607):335?338.
    [9] Cheng J, Han SS, Shao WW, Xu ZZ. Theory of X-ray in-line Gabor holography with partial coherent source. Acta Optica Sinica, 1999,19(5):596?603 (in Chinese with English abstract).
    [10] Wu XZ, Liu H. Clinical implementation of X-ray phase-contrast imaging: Theoretical foundations and design considerations. Medical Physics, 2003,30(8):2169?2179.
    [11] Wu XZ, Liu H. Clarification of aspects in in-line phase-sensitive X-ray imaging. Medical Physics, 2007,34(2):737?743.
    [12] W XZ, Liu H. Phase-Space formulation for phase-contrast X-ray imaging. Applied Optics, 2005,44(28):5847?5854.
    [13] Wu XZ, Liu H. A new theory of phase-contrast X-ray imaging based on Wigner distributions. Medical Physics, 2004,31(9): 2378?2384.
    [14] Donnelly EF, Price RR, Pickens DR. Experimental validation of the Wigner distributions theory of phase-contrast imaging. Medical Physics, 2005,32(4):928?931.
    [15] Born M, Wolf E. Principles of Optics. 6th ed., Cambridge: Cambridge University Press, 1980.
    [16] Spence JCH. Experimental High-Resolution Electron Microscopy. 2nd ed. Oxford: Clarendon Press, 1988.
    [17] Cowley JM. Diffraction Physics. 3rd ed. New York: North-Holland Pub. Co., 1995. 附中文参考文献:
    [3] 姜庆军,肖湘生,刘士远,肖体乔,陈敏.相干X线相衬成像的初步研究:离体大白鼠肝脏、肺脏成像实验.中国医学影像技术,2003,19(9):1116?1117.
    [9] 程静,韩申生,邵雯雯,徐至展.部分相干X射线相位成像研究.光学学报,1999,19(5):596?603. 龚绍润(1981-),男,湖南衡阳人,博士生,主要研究领域为X射线相衬成像技术. 刘泓(1951-),男,博士,教授,博士生导师,放射影像技术,光学仪器. 高峰(1963-),男,博士,教授,博士生导师,主要研究领域为医学成像与图像处理,生物医学光子学.
    Related
    Cited by
    Comments
    Comments
    分享到微博
    Submit
Get Citation

龚绍润,高峰,刘泓. X射线同轴相衬成像原理数值模拟及实验初探.软件学报,2009,20(5):1156-1165

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:May 29,2008
  • Revised:March 17,2009
You are the first2044680Visitors
Copyright: Institute of Software, Chinese Academy of Sciences Beijing ICP No. 05046678-4
Address:4# South Fourth Street, Zhong Guan Cun, Beijing 100190,Postal Code:100190
Phone:010-62562563 Fax:010-62562533 Email:jos@iscas.ac.cn
Technical Support:Beijing Qinyun Technology Development Co., Ltd.

Beijing Public Network Security No. 11040202500063