    Abstract:

    In order to meet the requirement for conformal intensity modulation inverse radiotherapy planning optimization processing, a new objective function is structured to target at the well defined objective area. This paper studies the parallel hybrid optimization strategy for inverse radiotherapy planning with the example of predominance combination of hybrid optimization strategy of simulation annealing and genetic algorithms, which formed a parallel general neighborhood searching hybrid optimization algorithm based on the uniform structure, and realizes the algorithm in a computer with multiple CPUs and multiple nuclei. It describes the dose distributions got with the algorithm for a virtual phantom and 5 clinical cases with the satisfying results. The results proves that this algorithm is effective and practical, which is a good platform for further research in parallel hybrid algorithm and the base for further development of the treatment planning system using biology guided radiotherapy technologies.

    Reference
    [1] Webb S. Intensity Modulated Radiation Therapy. Bristol: Institute of Physics Publishing, 2005. 250?278.
    [2] Webb S. Contemporary IMRT—Developing Physics and Clinical Implementation. Bristol: Philadelphia, Institute of Physics Publishing, 2005. 75?198.
    [3] Li YJ, Yao J, Yao D. Automatic beam angle selection in IMRT planning using genetic algorithm. Physics in Medicine Biology, 2004,49(10):1915?1932.
    [4] Webb S. Optimizing the planning of intensity-modulated radiotherapy. Physics in Medicine and Biology, 1994,39(12):2229?2246.
    [5] Redpath AT. Planning of beam intensity modulation using an advanced 3D dose calculation algorithm and a simulated annealing method. Radiotherapy and Oncology, 1998,49(3):295?304.
    [6] Li GL, Song G, Wu YC. Study on hybrid multi-objective optimization algorithm for inverse treatment planning of radiation therapy. Nuclear Techniques, 2007,30(3):222?226 (in Chinese with English abstract).
    [7] Li GL, Song G, Wu YC, Zhang J, Wang QJ. A multi-objective hybrid genetic based optimization for external beam radiation. Plasma Science & Technology, 2006,18(2):234?236.
    [8] Zhou ZD, Shu HZ, Yu WX, Luo LM. A combined multiobjective optimization of inverse planning in intensity modulated radiation therapy. Journal of Image and Graphics, 2005,10(7):905?909 (in Chinese with English abstract).
    [9] Wang L. Intelligent Optimization Algorithms with Applications. Beijing: Tsinghua University Press, 2001. 17?59, 118?141 (in Chinese).
    [10] Hu YM, Zhang HZ, Dai JR. Radiation Oncology Physics. Beijing: Atomic Energy Press, 1999. 516?528 (in Chinese).
    [11] Dai JR, Hu YM. Treatment planning for intensity-modulated radiation therapy. China Medical Devices Information, 2005,11(2): 9?12 (in Chinese with English abstract).
    [12] Yang RJ, Dai JR, Hu YM. Optimization of intensity-modulated radiation therapy. China Medical Devices Information, 2005,11(2):13?16 (in Chinese with English abstract).
    [13] Li MQ, Kou JS, Lin D, Li SQ. The Basic Theory and Application of Genetic Algorithms. Beijing: Science Press, 2002. 102?105 (in Chinese).
    [14] Wang XP, Cao LM. Genetic Algorithm-The Theory, Application and Software. Xi’an: Xi’an Jiaotong University Press, 2002. 77?79 (in Chinese).
    [15] Miao BH. Study of the visualization technology and dose calculation algorithm in 3D radiation treatment planning system and development of a PC based TPS software package [Ph.D. Thesis]. Beijing: Beijing University Press, 2002 (in Chinese with English abstract).
    [16] Zhang X, Han SK, Wu H, Xu B, Xiao GP, Bao SL. Clinical dosimetry verification for 3-D treatment planning system. Chinese Journal of Radiological Medicine and Protection, 2007,27(5):90?92 (in Chinese with English abstract).
    [17] Zhang X, Jin DW, Dai JR, Wang HL, Xiao GP, Bao SL. Clinical trial of 3D conformal radiotherapy treatment planning system. Chinese Journal of Scientific Instrument, 2007,28(9):1554?1557 (in Chinese with English abstract). 附中文参考文献:
    [6] 李国丽,宋钢,吴宜灿.放疗逆向计划中的混合多目标优化算法研究.核技术,2007,30(3):222?226.
    [8] 周正东,舒华忠,於文雪,罗立民.一种调强放射治疗逆向计划多目标混合优化方法研究.中国图像图形学报,2005,10(7):905?909.
    [9] 王凌.智能优化算法及其应用.北京:清华大学出版社,2001.17?59,118?141.
    [10] 胡逸民,张宏志,戴建荣.肿瘤放射物理学.北京:原子能出版社,1999.516?528.
    [11] 戴建荣,胡逸民.调强放疗的计划设计.中国医疗器械信息,2005,11(2):9?12.
    [12] 杨瑞杰,戴建荣,胡逸民.调强放射治疗的计划优化.中国医疗器械信息,2005,11(2):13?16.
    [13] 李敏强,寇纪淞,林丹,李书全.遗传算法的基本理论与应用.北京:科学出版社,2002.102?105.
    [14] 王小平,曹立军.遗传算法——理论、应用与软件实现.西安:西安交通大学出版社,2002.77?79.
    [15] 缪斌和.三维放疗计划系统可视化技术、剂量计算方法研究及TPS软件包研制[博士学位论文].北京:北京大学,2002.
    [16] 张新,韩树奎,吴昊,徐博,肖桂平,包尚联.三维治疗计划系统的临床剂量学验证.中华放射医学与防护杂志,2007,27(5):90?92.
    [17] 张新,金大伟,戴建荣,王慧亮,肖桂平,包尚联.三维放射治疗计划系统的临床实验.仪器仪表学报,2007,28(9):1554?1557.
    Cited by
Get Citation

王慧亮,黄斐增,包尚联.基于统一结构的并行混合放疗计划优化策略.软件学报,2009,20(5):1116-1122

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:February 18,2008
  • Revised:December 15,2008
You are the first2033269Visitors
Copyright: Institute of Software, Chinese Academy of Sciences Beijing ICP No. 05046678-4
Address:4# South Fourth Street, Zhong Guan Cun, Beijing 100190,Postal Code:100190
Phone:010-62562563 Fax:010-62562533 Email:jos@iscas.ac.cn
Technical Support:Beijing Qinyun Technology Development Co., Ltd.

Beijing Public Network Security No. 11040202500063